HARRIS INSTRUMENT CORPORATION

155 Johnson Drive, Delaware, OH 43015 Voice 740-369-3580  Fax 740-369-2653

 Non-Contact Measurement, Guiding and Detection Systems

 

   

SCAN-A-MIZER™ MONITORING SYSTEMS

 


 

The new SCAN-A-MIZERTM Series sensors from Harris Instrument Corporation provide a low cost, yet highly reliable alternative, to scanned laser measurement. SCAN-A-MIZERTM is very effective in applications that require width measurement, edge guiding, center guiding, position monitoring, and loop control of products manufactured in a continuous strip. Manufacturers that process textiles, non-wovens, metal strips, plastic films, rubber belting, paper, and building products can all save and profit from the advantages of using the new SCAN-A-MIZERTM technology.

      Applications

     Industries

     Features

  • Width Monitoring

  • Centerline Guide Position Monitoring
  • Edge Guide Position Monitoring
  • Loop Position Monitoring
  • End Alignment
  • Textiles
  • Metal Strips
  • Plastic Films
  • Non-Wovens
  • Rubber Belting
  • Paper
  • Building Products

 

  • Low Cost
  • Easy to Install – Minimum Fixturing
  • Vibration Resistant
  • Reliable – No Moving Parts
  • Long Life – 275-Year MTBF
  • Versatile – Many Application Configurations

SM-Series sensors consist of an emitter, a receiver and a power supply box with a twenty foot [2.13m] emitter-to-power supply cable and a twelve foot [3.65m] emitter-to-receiver cable. SCAN-A-MIZER™ emitters are available in twenty-inch [508mm] (Model SM-20), thirty-inch [762mm] (Model SM-30) or forty-inch [1016mm] (Model SM-40) units enclosed in a gold anodized, splash proof, extruded aluminum housing with a Lexan® viewing window. Receivers (Model SMR) are housed in black polane painted, aluminum enclosures with extruded aluminum mounting plate/bezel enclosing a viewing window and with horn blinder attached. The black polane painted, NEMA-12 SM-Series power supply enclosure contains a 90VAC to 240VAC auto-switching power supply to provide sensor power +12VDC @ 0.25Amp and –12VDC @ 0.05Amp.

Each emitter contains an array of Light Emitting Diodes (LEDs) that are lit sequentially. The receiver photocell detectors generate an electrical current whenever the pulsed light from the LEDs reach the photocell. Since the light from the emitter is pulsed at 20kHz, the current generated pulses at 20kHz, helping to prevent the interference of typical ambient light. For strobe light suppression, a 10Hz Low-Pass Filter is available on the output to filter out such light interference.

SCAN-A-MIZER™ SPECIFICATIONS

Four Analog Output Modes (all 100 Ohm Impedance):

First Edge 0-5VDC (20), 0-7VDC (30) or 0-10VDC (40);
Last Edge 0-5VDC (20), 0-7VDC (30) or 0-10VDC (40);
Width 0-5VDC (20), 0-7VDC (30) or 0-10VDC (40);
Centerline ±5VDC (20), ±7VDC (30) or ±10VDC (40).

Edge FAULT Open Collector:

Opens when no material in scanning area,
+24VDC Maximum @ 100mAmp.

Power Supply Dimensions (NEMA-12 rated):

8.25" [209mm] T x 6.28" [159mm] W x 3.78" [96mm] D;
Supports One or Two Sensors per Power Supply. Universal 90VAC-240VAC, Switchable, 50-60Hz at 2Amps Max, UL1950

System Power:

Universal 90VAC-240VAC, Switchable,
50-60Hz at 2Amps Max, UL1950.

Emitter-to-Receiver Separation:

Model SM-20 = 20" [508mm] to 72" [1829mm];
Model SM-30 = 30" [762mm] to 72" [1829mm];
Model SM-40 = 40" [1016mm] to 72" [1829mm].

Dynamic Range:

19" [482mm] (SM-20) to 39" [990mm] (SM-40).

(Dynamic Range is decreased by the ratio of the
product passline to emitter-to-receiver separation.)

Linearity:

Model SM-20 = 0.250% of range;
Model SM-30 = 0.167% of range;
Model SM-40 = 0.125% of range;
or 0.1" [2.5mm] @ 2 sigma for Any Output.

Sensor Dimensions:

Emitter = Model SM-20 – 24.2" [614mm] L
Model SM-30 – 34.2" [869mm] L
Model SM-40 – 44.2" [1123mm] L x
3" [76mm] W x 4.125" [105mm] H.
Receiver = 6.6" [168mm] L x 3" [76mm] W x 3.6" [91mm] H.

 


SCAN-A-MIZER™ Information Request Form

Select the items that apply, and then let us know how to contact you.

Send product literature
Send company literature
Send Quotation

Have a salesperson contact me

 

Name:   MI:   Last Name:
Title:
Company:
Address 1:
Address 2:
City:   State:   Zip Code:
Country:
Phone:   Fax:
E-mail:
  

Application Specifications

System Type: 

Process Type: (Extruder, Textile Line, Steel Continuous Line, Etc.)

Material Type: (Steel, Rubber, Film, Paper, Etc.)

Material Density: Opaque  Clear  Translucent

Minimum Width:  Maximum Width: inches mm cm

Minimum Thickness:  Maximum Thickness: inches mm cm

Line Speed: FPM M/S

What is the Strip/Material Side-to-Side (Lateral) Movement during normal running conditions:

inches mm cm

Does the strip/material passline remain flat or move vertically: Flat Passline  Changing Passline

If any bounce, flutter, etc... please specify inches mm cm Type:

Power Requirements: 110VAC  220VAC  60Hz  50Hz

Processor Options: Digital Display  Analog Output  RS-232 Port  Relay Alarms

                           SPC Printed Reports  SPC Serial Data File

Are there any mounting restrictions: Yes  No  (If yes, please describe)

Is a custom mounting frame required: Yes No

 


Send mail to webmaster with questions or comments about this web site.
Copyright © 2007 Harris Instrument Corporation
Last modified: 03/05/09